TY - JOUR
T1 - Alternative bearings in total knee arthroplasty
T2 - risk of early revision compared to traditional bearings: An analysis of 62,177 primary cases
AU - Inacio, Maria C.S.
AU - Cafri, Guy
AU - Paxton, Elizabeth W.
AU - Kurtz, Steven M.
AU - Namba, Robert S.
PY - 2013/1/1
Y1 - 2013/1/1
N2 - Background and purpose There is no substantial clinical evidence for the superiority of alternative bearings in total knee arthroplasty (TKA). We compared the short-term revision risk in alternative surface bearing knees (oxidized zirconium (OZ) femoral implants or highly crosslinked polyethylene (HXLPE) inserts) with that for traditional bearings (cobalt-chromium (CoCR) on conventional polyethelene (CPE)). The risk of revision with commercially available HXLPE inserts was also evaluated. Methods All 62,177 primary TKA cases registered in a Total Joint Replacement Registry between April 2001 and December 2010 were retrospectively analyzed. The endpoints for the analysis were all-cause revisions, septic revisions, or aseptic revisions. Bearing surfaces were categorized as OZ-CPE, CoCr-HXLPE, or CoCr-CPE. HXLPE inserts were stratified according to brand name. Confounding was addressed using propensity score weights. Marginal Cox-regression models adjusting for surgeon clustering were used. Results The proportion of females was 62%. Average age was 68 (SD 9.3) years, and median follow-up time was 2.8 (IQR 1.2-4.9) years. After adjustments, the risks of all-cause, aseptic, and septic revision with CoCr-HXLPE and OZ-CPE bearings were not statistically significantly higher than with traditional CoCr-CPE bearings. No specific brand of HXLPE insert was associated with a higher risk of all-cause, aseptic, or septic revision compared to CoCr-CPE. Interpretation At least in the short term, none of the alternative knee bearings evaluated (CoCr-HXLPE or OZ-CPE) had a greater risk of all-cause, aseptic, and septic revision than traditional CoCr-CPE bearings.
AB - Background and purpose There is no substantial clinical evidence for the superiority of alternative bearings in total knee arthroplasty (TKA). We compared the short-term revision risk in alternative surface bearing knees (oxidized zirconium (OZ) femoral implants or highly crosslinked polyethylene (HXLPE) inserts) with that for traditional bearings (cobalt-chromium (CoCR) on conventional polyethelene (CPE)). The risk of revision with commercially available HXLPE inserts was also evaluated. Methods All 62,177 primary TKA cases registered in a Total Joint Replacement Registry between April 2001 and December 2010 were retrospectively analyzed. The endpoints for the analysis were all-cause revisions, septic revisions, or aseptic revisions. Bearing surfaces were categorized as OZ-CPE, CoCr-HXLPE, or CoCr-CPE. HXLPE inserts were stratified according to brand name. Confounding was addressed using propensity score weights. Marginal Cox-regression models adjusting for surgeon clustering were used. Results The proportion of females was 62%. Average age was 68 (SD 9.3) years, and median follow-up time was 2.8 (IQR 1.2-4.9) years. After adjustments, the risks of all-cause, aseptic, and septic revision with CoCr-HXLPE and OZ-CPE bearings were not statistically significantly higher than with traditional CoCr-CPE bearings. No specific brand of HXLPE insert was associated with a higher risk of all-cause, aseptic, or septic revision compared to CoCr-CPE. Interpretation At least in the short term, none of the alternative knee bearings evaluated (CoCr-HXLPE or OZ-CPE) had a greater risk of all-cause, aseptic, and septic revision than traditional CoCr-CPE bearings.
UR - http://www.scopus.com/inward/record.url?scp=84876359713&partnerID=8YFLogxK
U2 - 10.3109/17453674.2013.784660
DO - 10.3109/17453674.2013.784660
M3 - Article
C2 - 23485105
AN - SCOPUS:84876359713
SN - 1745-3674
VL - 84
SP - 145
EP - 152
JO - Acta Orthopaedica
JF - Acta Orthopaedica
IS - 2
ER -