TY - JOUR
T1 - Biological variation of high sensitivity cardiac troponin-T in stable dialysis patients
T2 - Implications for clinical practice
AU - Fahim, Magid
AU - Hayen, Andrew
AU - Horvath, Andrea
AU - Dimeski, Goce
AU - Coburn, Amanda
AU - Tan, Ken-Soon
AU - Johnson, David
AU - Craig, Jonathan
AU - Campbell, Scott
AU - Hawley, Carmel
PY - 2015/4/1
Y1 - 2015/4/1
N2 - Background: Changes in high sensitivity cardiac troponin-T (hs-cTnT) concentrations may reflect either acute myocardial injury or biological variation. Distinguishing between these entities is essential to accurate diagnosis, however, the biological variation of hs-cTnT in dialysis population is currently unknown. We sought to estimate the within- and between-person coefficients of variation of hs-cTnT in stable dialysis patients, and derive the critical difference between measurements needed to exclude biological variation with 99% confidence. Methods: Fifty-five prevalent haemo- and peritoneal-dialysis patients attending two metropolitan hospitals were assessed on 10 consecutive occasions; weekly for 5 weeks then monthly for 4 months. Assessments were conducted at the same dialysis cycle time-point and entailed hs-cTnT testing, clinical review, electrocardiography, and bioimpedance spectroscopy. Patients were excluded if they developed clinical or physiological instability. Results: In total 137 weekly and 114 monthly hs-cTnT measurements from 42 stable patients were analysed. Respective between- and within-person coefficients of variation were 83% and 7.9% for weekly measurements, and 79% and 12.6% for monthly measurements. Within-person variation was unaffected by dialysis modality or cardiac co-morbidity. The bidirectional 99% reference change value was -25% and +33% for weekly measurements, and -37% and +58% for monthly measurements. Conclusions: The between-person variation of hs-cTnT in the dialysis population is markedly greater than within-person variation indicating that hs-cTnT testing is best applied in this population using a relative change strategy. An increase of 33% or a reduction of 25% in serial hs-cTnT concentrations measured at weekly intervals excludes change due to analytical and biological variation alone with 99% confidence.
AB - Background: Changes in high sensitivity cardiac troponin-T (hs-cTnT) concentrations may reflect either acute myocardial injury or biological variation. Distinguishing between these entities is essential to accurate diagnosis, however, the biological variation of hs-cTnT in dialysis population is currently unknown. We sought to estimate the within- and between-person coefficients of variation of hs-cTnT in stable dialysis patients, and derive the critical difference between measurements needed to exclude biological variation with 99% confidence. Methods: Fifty-five prevalent haemo- and peritoneal-dialysis patients attending two metropolitan hospitals were assessed on 10 consecutive occasions; weekly for 5 weeks then monthly for 4 months. Assessments were conducted at the same dialysis cycle time-point and entailed hs-cTnT testing, clinical review, electrocardiography, and bioimpedance spectroscopy. Patients were excluded if they developed clinical or physiological instability. Results: In total 137 weekly and 114 monthly hs-cTnT measurements from 42 stable patients were analysed. Respective between- and within-person coefficients of variation were 83% and 7.9% for weekly measurements, and 79% and 12.6% for monthly measurements. Within-person variation was unaffected by dialysis modality or cardiac co-morbidity. The bidirectional 99% reference change value was -25% and +33% for weekly measurements, and -37% and +58% for monthly measurements. Conclusions: The between-person variation of hs-cTnT in the dialysis population is markedly greater than within-person variation indicating that hs-cTnT testing is best applied in this population using a relative change strategy. An increase of 33% or a reduction of 25% in serial hs-cTnT concentrations measured at weekly intervals excludes change due to analytical and biological variation alone with 99% confidence.
KW - renal dialysis
KW - troponin T
KW - variability
UR - http://www.scopus.com/inward/record.url?scp=84928010996&partnerID=8YFLogxK
U2 - 10.1515/cclm-2014-0838
DO - 10.1515/cclm-2014-0838
M3 - Article
VL - 53
SP - 715
EP - 722
JO - Clinical Chemistry and Laboratory Medicine
JF - Clinical Chemistry and Laboratory Medicine
SN - 1434-6621
IS - 5
ER -