Computational assessment of the effect of polyethylene wear rate, mantle thickness, and porosity on the mechanical failure of the acetabular cement mantle

O Coultrup, C Hunt, B Michael Wroblewski, Mark Taylor

    Research output: Contribution to journalArticlepeer-review

    22 Citations (Scopus)

    Abstract

    Clinical studies have revealed that aseptic loosening is the dominant cause of failure in total hip arthroplasty, particularly for the acetabular component. For a cemented polyethylene cup, failure is generally accompanied by the formation of fibrous tissue at the cement-bone interface. A variety of reasons for the formation of this tissue have been suggested, including osteolysis and mechanical overload at the cement-bone interface. In this study, a computational cement damage accumulation method was used to investigate the effect of polyethylene cup penetration, cement mantle thickness, and cement porosity on the number of cycles required to achieve mechanical fatigue failure of the cement mantle. Cup penetration was found to increase cement mantle stresses, resulting in a reduction in cement mantle fatigue life of 9% to 11% for a high cup penetration rate. The effect of using a thin (2 mm) over a thick (4 mm) cement mantle also reduced cement mantle fatigue life between 9% and 11%, and greatly raised cancellous bone stresses. Cement porosity was found to have very little effect on cement mantle fatigue life. Failure modes and cement stresses involved suggest that only extreme combinations of a thin cement mantle and high cup penetration may lead to mechanical failure of the cement mantle, thereby allowing wear debris access to the cement-bone interface. A thin cement mantle may also lead to the mechanical overload of the cement-bone interface. In this manner, the authors suggest that the mechanical factors may contribute to the failure mode of cemented polyethylene cups.

    Original languageEnglish
    Pages (from-to)565-570
    Number of pages6
    JournalJournal of Orthopaedic Research
    Volume28
    Issue number5
    DOIs
    Publication statusPublished - May 2010

    Keywords

    • Acetabulum
    • Aseptic loosening
    • Bone cement
    • Cup penetration
    • Finite element analysis

    Fingerprint Dive into the research topics of 'Computational assessment of the effect of polyethylene wear rate, mantle thickness, and porosity on the mechanical failure of the acetabular cement mantle'. Together they form a unique fingerprint.

    Cite this