TY - JOUR
T1 - Effective Preparation of Plasmodium vivax Field Isolates for High-Throughput Whole Genome Sequencing
AU - Auburn, Sarah
AU - Marfurt, J
AU - Maslen, Gareth
AU - Campino, Susana
AU - Rubio, Valentin
AU - Manske, Magnus
AU - MacHunter, B
AU - Kenangalem, E
AU - Noviyanti, Rintis
AU - Trianty, Leily
AU - Sebayang, Boni
AU - Wirjanata, Grennady
AU - Sriprawat, Kanlaya
AU - Alcock, Daniel
AU - MacInnis, Bronwyn
AU - Miotto, Olivo
AU - Clark, Taane
AU - Russell, Bruce
AU - Anstey, Nicholas
AU - Nosten, Francois
AU - Kwiatkowski, Dominic
AU - Price, Ric
PY - 2013/1/4
Y1 - 2013/1/4
N2 - Whole genome sequencing (WGS) of Plasmodium vivax is problematic due to the reliance on clinical isolates which are generally low in parasitaemia and sample volume. Furthermore, clinical isolates contain a significant contaminating background of host DNA which confounds efforts to map short read sequence of the target P. vivax DNA. Here, we discuss a methodology to significantly improve the success of P. vivax WGS on natural (non-adapted) patient isolates. Using 37 patient isolates from Indonesia, Thailand, and travellers, we assessed the application of CF11-based white blood cell filtration alone and in combination with short term ex vivo schizont maturation. Although CF11 filtration reduced human DNA contamination in 8 Indonesian isolates tested, additional short-term culture increased the P. vivax DNA yield from a median of 0.15 to 6.2 ng μl-1 packed red blood cells (pRBCs) (p = 0.001) and reduced the human DNA percentage from a median of 33.9% to 6.22% (p = 0.008). Furthermore, post-CF11 and culture samples from Thailand gave a median P. vivax DNA yield of 2.34 ng μl-1 pRBCs, and 2.65% human DNA. In 22 P. vivax patient isolates prepared with the 2-step method, we demonstrate high depth (median 654X coverage) and breadth (≥89%) of coverage on the Illumina GAII and HiSeq platforms. In contrast to the A+T-rich P. falciparum genome, negligible bias was observed in coverage depth between coding and non-coding regions of the P. vivax genome. This uniform coverage will greatly facilitate the detection of SNPs and copy number variants across the genome, enabling unbiased exploration of the natural diversity in P. vivax populations.
AB - Whole genome sequencing (WGS) of Plasmodium vivax is problematic due to the reliance on clinical isolates which are generally low in parasitaemia and sample volume. Furthermore, clinical isolates contain a significant contaminating background of host DNA which confounds efforts to map short read sequence of the target P. vivax DNA. Here, we discuss a methodology to significantly improve the success of P. vivax WGS on natural (non-adapted) patient isolates. Using 37 patient isolates from Indonesia, Thailand, and travellers, we assessed the application of CF11-based white blood cell filtration alone and in combination with short term ex vivo schizont maturation. Although CF11 filtration reduced human DNA contamination in 8 Indonesian isolates tested, additional short-term culture increased the P. vivax DNA yield from a median of 0.15 to 6.2 ng μl-1 packed red blood cells (pRBCs) (p = 0.001) and reduced the human DNA percentage from a median of 33.9% to 6.22% (p = 0.008). Furthermore, post-CF11 and culture samples from Thailand gave a median P. vivax DNA yield of 2.34 ng μl-1 pRBCs, and 2.65% human DNA. In 22 P. vivax patient isolates prepared with the 2-step method, we demonstrate high depth (median 654X coverage) and breadth (≥89%) of coverage on the Illumina GAII and HiSeq platforms. In contrast to the A+T-rich P. falciparum genome, negligible bias was observed in coverage depth between coding and non-coding regions of the P. vivax genome. This uniform coverage will greatly facilitate the detection of SNPs and copy number variants across the genome, enabling unbiased exploration of the natural diversity in P. vivax populations.
UR - http://www.scopus.com/inward/record.url?scp=84871885956&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0053160
DO - 10.1371/journal.pone.0053160
M3 - Article
SN - 1932-6203
VL - 8
SP - e53160
JO - PLoS One
JF - PLoS One
IS - 1
M1 - e53160
ER -