Abstract
The structural performance of a reinforced concrete is influenced by the properties of the reinforcing element and the concrete interface. Therefore, investigating the pull-out strength and bond stress vs. slip relationship between components of the reinforced concrete are very important. This paper presents a numerical method to study the pull-out behaviour of galvanised steel strips in aerated concrete. A local bond-slip relationship is determined using experimental and theoretical analyses and is then implemented to the finite element simulation through the user-defined subroutine of ABAQUS software. The effect of strip geometry and mechanical properties of the aerated concrete on the pull-out force is also investigated. Comparison between the experimental, theoretical and FE simulation results shows very good agreement. It was shown that a trilinear bond-slip model is suitable for the modelling of steel strip and concrete interface.
| Original language | English |
|---|---|
| Pages (from-to) | 982-1001 |
| Number of pages | 20 |
| Journal | European Journal of Environmental and Civil Engineering |
| Volume | 17 |
| Issue number | 10 |
| DOIs | |
| Publication status | Published - 1 Nov 2013 |
| Externally published | Yes |
Keywords
- bond stress vs. slip relationship
- foam concrete
- pull-out test
- steel strip
Fingerprint
Dive into the research topics of 'Experimental and numerical analysis pull-out strength of steel strip in foam concrete'. Together they form a unique fingerprint.Cite this