TY - JOUR
T1 - Surface Laplacian of scalp electrical signals and independent component analysis resolve EMG contamination of electroencephalogram
AU - Fitzgibbon, Sean
AU - DeLosAngeles, Dylan
AU - Lewis, Trent
AU - Powers, David
AU - Whitham, Emma
AU - Willoughby, John
AU - Pope, Kenneth
PY - 2015/9/1
Y1 - 2015/9/1
N2 - The serious impact of electromyogram (EMG) contamination of electroencephalogram (EEG) is well recognised. The objective of this research is to demonstrate that combining independent component analysis with the surface Laplacian can eliminate EMG contamination of the EEG, and to validate that this processing does not degrade expected neurogenic signals. The method involves sequential application of ICA, using a manual procedure to identify and discard EMG components, followed by the surface Laplacian. The extent of decontamination is quantified by comparing processed EEG with EMG-free data that was recorded during pharmacologically induced neuromuscular paralysis. The combination of the ICA procedure and the surface Laplacian, with a flexible spherical spline, results in a strong suppression of EMG contamination at all scalp sites and frequencies. Furthermore, the ICA and surface Laplacian procedure does not impair the detection of well-known, cerebral responses; alpha activity with eyes-closed; ERP components (N1, P2) in response to an auditory oddball task; and steady state responses to photic and auditory stimulation. Finally, more flexible spherical splines increase the suppression of EMG by the surface Laplacian. We postulate this is due to ICA enabling the removal of local muscle sources of EMG contamination and the Laplacian transform being insensitive to distant (postural) muscle EMG contamination.
AB - The serious impact of electromyogram (EMG) contamination of electroencephalogram (EEG) is well recognised. The objective of this research is to demonstrate that combining independent component analysis with the surface Laplacian can eliminate EMG contamination of the EEG, and to validate that this processing does not degrade expected neurogenic signals. The method involves sequential application of ICA, using a manual procedure to identify and discard EMG components, followed by the surface Laplacian. The extent of decontamination is quantified by comparing processed EEG with EMG-free data that was recorded during pharmacologically induced neuromuscular paralysis. The combination of the ICA procedure and the surface Laplacian, with a flexible spherical spline, results in a strong suppression of EMG contamination at all scalp sites and frequencies. Furthermore, the ICA and surface Laplacian procedure does not impair the detection of well-known, cerebral responses; alpha activity with eyes-closed; ERP components (N1, P2) in response to an auditory oddball task; and steady state responses to photic and auditory stimulation. Finally, more flexible spherical splines increase the suppression of EMG by the surface Laplacian. We postulate this is due to ICA enabling the removal of local muscle sources of EMG contamination and the Laplacian transform being insensitive to distant (postural) muscle EMG contamination.
KW - EEG
KW - Electromyogram
KW - Evoked response
KW - Independent component analysis
KW - Oddball task
KW - Steady state response
KW - Surface Laplacian
UR - http://www.scopus.com/inward/record.url?scp=84939190143&partnerID=8YFLogxK
U2 - 10.1016/j.ijpsycho.2014.10.006
DO - 10.1016/j.ijpsycho.2014.10.006
M3 - Article
SN - 0167-8760
VL - 97
SP - 277
EP - 284
JO - International Journal of Psychophysiology
JF - International Journal of Psychophysiology
IS - 3
ER -