The O-Arm as an Additional Tool to Confirm Optimal Ventricular Tip Position—A Technical Note

Jorn Van Der Veken, Jamie Miller, Santosh Poonnoose

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

Background: Ventricular catheter placement can be a challenging procedure when treating patients with slit ventricles, despite the use of a neuronavigation system. Methods: We report the case of 3 patients with idiopathic intracranial hypertension who had required revision of their ventricular catheter due to malpositioning, despite initial placement using neuronavigation. Owing to the absence of intraoperative computed tomography in our center, we used the O-arm imaging system to confirm placement of the optimal ventricular tip position intraoperatively. Results: Optimal ventricular drain position was achieved in all 3 patients. Conclusions: This short technical note describes an easy technique for using the O-arm to confirm the optimal ventricular drain position.

Original languageEnglish
Pages (from-to)68-70
Number of pages3
JournalWorld Neurosurgery
Volume163
DOIs
Publication statusPublished - Jul 2022

Keywords

  • Hydrocephalus
  • O-arm
  • Ventriculoperitoneal shunt

Fingerprint

Dive into the research topics of 'The O-Arm as an Additional Tool to Confirm Optimal Ventricular Tip Position—A Technical Note'. Together they form a unique fingerprint.

Cite this